Zhejiang Chloe Electric Co., Ltd. — Insulators and insulation support for switchgear, busbar and power systems

KLY insulators in every height and thread
The KLY family covers a wide range of heights and thread sizes for busbar and panel mounting, in red, grey, yellow and white shells, each with its own item number.

Order by height, thread, material and colour
Every item number carries its full configuration: overall height, thread at each end, shell material and the colour used for phase marking. Nothing has to be inferred from a photo.

ZJ post, porcelain and composite insulators
ZJ post insulators serve 10–35 kV switchgear; porcelain and composite types cover outdoor and line duties. All 28 series carry their own item numbers.
Insulator families for switchgear, busbar and power systems
28 series and 2651 item numbers — stand-off, busbar support, post, porcelain and composite insulators, plus insulator supports and custom parts.


















- Product photograph pending



- Product photograph pending



- Product photograph pending
- Product photograph pending
Insulators for switchgear, busbar and power systems
Series, heights, threads, materials and packing, described the way the shop builds them.
Insulator families for switchgear and busbar
Chloe Electric makes insulators and insulation support for low- and medium-voltage equipment. The KLY, MNS, EL and SM stand-off families centre the range, with ZJ post, porcelain and composite insulators beside them, plus insulator supports and custom parts.
The range covers 28 series, 210 product lines and 2651 item numbers, each with its own specification and unit.
- KLY / MNS / EL / SM stand-off insulators for busbar and panel mounting
- ZJ post insulators for 10–35 kV switchgear
- Porcelain and composite insulators for outdoor and line duties
- CJ / CT supports and custom non-standard parts to drawing

The range by the numbers
- 28Insulator series families
- 2,651Item numbers in the range
- 210Product lines
- 1,257Item numbers with a photograph
From shell and core to a packed insulator
Moulded shells, machined cores, sorted colours and the bench where an insulator is checked before it is boxed.
Start An EnquiryWhere the insulators go
Switchgear and distribution cabinets, busbar framing, transformer and motor terminals, and the overhead lines they support.
6 applications

LV Switchgear
LV Switchgear Busbar Support
SM stand-off insulators carrying the main busbar, with the shell colour carrying the phase marking instead of a label that peels off.
A low-voltage switchgear assemblyEast China2026

Distribution Cabinets
Distribution Cabinet Panel Mounting
KLY and EL insulators on a cabinet frame whose hole pattern was drawn before the insulator was chosen.
A distribution cabinet builder with an existing frameZhejiang, China2026

MV Switchgear
MV Switchgear Post Insulators
ZJ post insulators on the medium-voltage side, where the flange and thread are written against the cabinet drawing.
A 10–35 kV switchgear buildEast China2025

Overhead Lines
Overhead Line Insulation
Porcelain and composite insulators for outdoor line duties, chosen for the weather the string will sit in.
An overhead distribution lineNorth China2025

Transformer & Motor
Transformer & Motor Terminal Insulation
Terminal-board insulators sized by the thread the winding lead already uses, in epoxy and porcelain.
A motor and transformer builderSouth China2026

Custom & Supports
Custom Non-Standard Supports
Non-standard insulators and CJ/CT supports quoted from a drawing, ordered so the site kit does not run short of a fixing.
A custom panel programmeExport order2026
How an order runs
- 01
Enquiry
The equipment, the voltage class and the item numbers you are considering — or a drawing if nothing in the range fits. A photo of the mounting panel and the busbar size answers most of it.
- 02
Selection & Confirmation
We read the specification back to you: height, thread at each end, shell material, colour and unit. Where a standard line does not fit, the alternative is stated before price is discussed.
- 03
Quotation & Lead Time
Price, lead time and packing detail for the exact item numbers quoted, including the carton dimensions and the packing for each line.
- 04
Production & Dispatch
Confirmed lines follow the agreed schedule. Packing uses the carton dimensions in the item specification and the shipment goes out against the confirmed list.
Questions we get before a quotation
They read our SM insulator configuration back to us before quoting and confirmed the thread at each end against our panel drawing.
The busbar spacing on our cabinet was not a standard one. A drawing went over, a variant came back, and it dropped onto the existing frame.
Three families and two colours on one order, and the packing list matched the item numbers exactly. That is what keeps goods-in short.
A height we could not find in the range was quoted from a drawing. The reply came back with the item number, unit and packing before we had paid a deposit.
What actually decides an insulator selection

Choosing the Voltage Class and Height: Three Inputs the Specification Cannot Decide
The ZJ family is listed for 10, 24 and 35 kV and the composite FZSW3 for 12, 24 and 40.5 kV. Picking one is easy; keeping the pick honest means naming the three things a specification cannot decide about your equipment.
- Sep 16, 2026
- Gao Yuan
- Selection
- 7 min read

Epoxy, Porcelain or Composite: Reading an Insulator Specification
Inside one family, every difference between two item numbers is written out in the item description. Once you know which words matter, most of the selection is already made.
- Aug 19, 2026
- Lin Xiaoyun
- Variants
- 6 min read

Red, Grey and Yellow Are a Marking Convention, Not a Rating
The colour on the order line is the colour of the phase marking on the panel. It is worth being precise about what it does and does not tell the assembly team.
- Jul 22, 2026
- Xu Ling
- Ordering
- 5 min read

Height, Thread and the Panel in Between
The failures that turn an insulator order into a site problem are almost never electrical. They are an insulator that is too short for the spacing it stands in, or a thread that will not start on the fixing already drilled.
- Jun 11, 2026
- Zhao Gang
- Selection
- 6 min read
Industries the insulators are built into
Switchgear, busbar systems, transformers and the overhead and substation equipment they sit in.